Sunday, June 3, 2012

Modern electrical motors,Modern electrical motors,slip-ring motor,slip ring motor,squirrel cage motor,syncronous motor,torque motor,






Modern electrical motors are available in many different forms, such as single phase motors, three-phase motors, brake motors, synchronous motors, Asynchronous Motors, special customised motors, two speed motors, three speed motors, and so on, all with their own performance and characteristics.
For each type of motor there are many different mounting arrangements, for example foot mounting, flange mounting or combined foot and flange mounting. The cooling method can also differ very much, from the simplest motor with free self-circulation of air to a more complex motor with totally enclosed air-water cooling with an interchangeable cassette type of cooler.
To ensure a long lifetime for the motor it is important to keep it with the correct degree of protection when under heavy-duty conditions in a servere environment. The two letters IP (International Protection) state the degree of protection followed by two digits, the first of which indicates the degree of protection against contact and penetration of solid objects, whereas the second states the motor's degree of protection against water.
The end of the motor is defined in the IEC-standard as follows:
  • The D-end is normally the drive end of the motor.
  • The N-end is normally the non-drive end of the motor.
Asynchronous Motor Construction
Squirrel Cage Motors
In this book the focus has been placed on the squirrel cage motor, the most common type of motor on the market. It is relatively cheap and the maintenance cost is normally low. There are many different manufacturers represented on the market, selling at various prices. Not all motors have the same performance and quality as for example motors from ABB. High efficiency enables significant savings in energy costs during the motor's normal endurance. The low level of noise is something else that is of interest today, as is the ability to withstand severe environments.
There are also other parameters that differ. The design of the rotor affects the starting current and torque and the variation can be really large between different manufacturers for the same power rating. When Using a Softstarter it is good if the motor has a high starting torque at Direct-on-line (D.O.L) start. When these motors are used together with a softstarter it is possible to reduce the starting current further when compared to motors with low starting torque. The number of poles also affects the technical data. A motor with two poles often has a lower starting torque than motors with four or more poles.
Current Diagram For A Typical Squirrel Cage Motor

Torque Diagram For A Typical Squirrel Cage Motor
Voltage
Three-phase single speed motors can normally be connected for two different voltage levels. The three stator windings are connected in star (Y) or delta (D).
The windings can also be connected in series or parallel, Y or YY for instance. If the rating plate on a squirrel cage motor indicates voltages for both the star and delta connection, it is possible to use the motor for both 230 V, and 400 V as an example.
The winding is delta connected at 230 V and if the main voltage is 400 V, the Y-connection is used.
When changing the main voltage it is important to remember that for the same power rating the rated motor current will change depending on the voltage level.
The method for connecting the motor to the Terminal Blocks for Star or Delta Connection is shown in the picture below.
Delta Connection

Wiring Diagram For Y & Delta Connection
Star Connection
Power Factor
A motor always consumes active power, which it converts into mechanical action. Reactive power is also required for the magnetisation of the motor but it doesn't perform any action. In the diagram below the active and reactive power is represented by P and Q, which together give the power S.
The ratio between the active power (kW) and the reactive power (kVA) is known as the power factor, and is often designated as the cos φ. A normal value is between 0.7 and 0.9, when running where the lower value is for small motors and the higher for large ones.
Diagram indicating P, Q, S and Cos φ
Speed
The speed of an AC motor depends on two things: the number of poles of the stator winding and the main frequency. At 50 Hz, a motor will run at a speed related to a constant of 6000 divided by the number of poles and for a 60 Hz motor the constant is 7200 rpm.
To calculate the speed of a motor, the following formula can be used:
Formula To Calculate The Speed Of A Motor
This speed is the synchronous speed and a squirrel-cage or a slip-ring motor can never reach it. At unloaded condition the speed will be very close to synchronous speed and will then drop when the motor is loaded.
The difference between the synchronous and asynchronous speed also named rated speed is "the slip" and it is possible to calculate this by using the following formula:
The Slip Formula
Table for synchronous speed at different number of poles and frequency:
No. of poles 50 Hz 60 Hz
2 3000 3600
4 1500 1800
6 1000 1200
8 750 900
10 600 720
12 500 600
16 375 450
20 300 360
Diagram Showing Syncronous Speed Vs. Rated Speed
Torque
The starting torque for a motor differs significantly depending on the size of the motor. A small motor, e.g. ≤ 30 kW, normally has a value of between 2.5 and 3 times the rated torque, and for a medium size motor, say up to 250 kW, a typical value is between 2 to 2.5 times the rated torque. Really big motors have a tendency to have a very low starting torque, sometimes even lower than the rated torque. It is not possible to start such a motor fully loaded not even at D.O.L start.
The rated torque of a motor can be calculated using the following formula:
Formula To Calculate Torque Of A Motor

Torque Diagram For A Typical Squirrel Cage Motor
Slip-Ring Motors
In some cases when a D.O.L start is not permitted due to the high starting current, or when starting with a star-delta starter will give too low starting torque, a slip-ring motor is used. The motor is started by changing the rotor resistance and when speeding up the resistance is gradually removed until the rated speed is achieved and the motor is working at the equivalent rate of a standard squirrel-cage motor.
The advantage of a slip-ring motor is that the starting current will be lower and it is possible to adjust the starting torque up to the maximum torque. In general, if a softstarter is going to be used for this application you also need to replace the motor.
Torque Diagram For A Slip-Ring Motor

Current Diagram For A Slip-Ring Motor











If you are looking for  motor and Ac drives, please contact us.  We will do our best to help you find the Inverter Drives that you are looking for at the most competitive prices possible.
Most of our standard Items are available Ex-Stock
 We can provide Third Party Services all over world.
For any other related information feel free to contact us.